Showing results: 181 - 195 of 219 items found.
-
Model 4804B-7 -
ICS Electronics
* F30145 firmware converts printable ASCII character strings into the ANSI X3.28 serial protocol.* User selectable single-ended RS-232 and differential RS-422/RS-485 serial signals.* Can be used to replace obsolete ICS 4814 Interfaces.* Connect to the rear panel with a GPIB Flat-ribbon cable or with a GPIB Connector/Address Switch Cable.* Runs on 5 Vdc regulated or 5.5 to 15 V unregulated power.
-
Model 2399 -
ICS Electronics
* Converts ANSI X3.28 commandslinto Modbus RTU packets.* New 32 Address Mode supports multi-channel Modbus Controllers like the Watlow MLS300.* Control Modbus RTU devices from any ASCII serial source.* Serial ports support RS-232 and 2-wire/4-wire RS-485 signals.* Includes serial baud rate conversion.* Internal logic is IEEE-488.2 compatible and uses SCPI commands for configurtion setup.* 2399 mounts on a DIN rail or on any flat panel.* Inexpensive way to maintain manufacturing equipment such as semiconductor fusion chambers, etc as the ANSI Controllers become obsolete.* Application Note AB23-3 describes how to use the 2399 to replace obsolete Watlow Controllers in the Axcelis/Fusion Gemini Asher.* 2399 Serial Keyboard Program lets you control and setup the 2399 and test the ANSI modes.* 239x Table Loader Program uploads ANSI Command Table entries from an Excel csv file.
-
0001-011 -
VI Control Systems Ltd.
A general purpose interface board for Mircromint's Answer Man Junior. Jumpers select one of three communication interfaces (RS-232, RS-485, or fiber optic RS-232). 12 bit ADCs and DACs are added for higher precision AD conversions. Answer Man Junior is included with the board.
-
Elmeasure India Pvt. Ltd
Multiple branches of load can be monitored togetherCan group the device as 3 phase load and single phase loadFaster communication through RS485 port (Modbus protocol)Simultaneous sampling of Volts and AmpsAccuracy Class 1.0 as per IEC 62053-21 & Class 0.5 as per IEC 62053-22 StandardsDisplays more than 25 parameters
-
EZA Series -
TDK-Lambda Corp.
*1U Rackmount Bidirectional Isolated DC-DC*2.5 kW: 48 Vdc (Battery) Û 320 Vdc (Grid)*11 kW: 240 Vdc (Battery) Û 320 Vdc (Grid)*2.2 kVac up to 3 kVac Isolation*High Efficiency > 92%*RS-485 Communications and Control*For Energy Regeneration applications
-
T8448 -
COMET SYSTEM, s.r.o.
CO2 concentration and temperature transmitter with serial RS485 output is specially designed for use in exacting interiors in building energy management and HVAC systems. It designed for easy installation on ordinary KU68 wiring boxes for household switches and sockets. Large dual line LCD is possible to switch off. Computerized design ensures long term stability and fail indication. Transmitter is designed for use in non-aggressive environment.
-
SparkFun Electronics
This is the newest revision of this board and this breakout board pairs an SP3485 RS-485 transceiver with an FT232RL USB UART IC to convert a USB stream to RS-485. The SP3485 is a half-duplex transceiver, so it can only communicate one way at a time, but it can reach transmission speeds of up to 10Mbps.
-
Analog Devices Inc.
The RS-485 specification meets the requirements for a truly multipoint communications network, and the standard specifies up to 32 drivers and 32 receivers on a single (2-wire) bus. Some RS-485 transceivers modify the input impedance to allow up to 8× more nodes to be connected to the same bus. Analog Devices offers a wide range of standard RS-485/RS-422 transceivers and iCoupler® isolated RS-485/RS-422 transceivers to suit many applications.
-
Wuntronic GmbH
RS485 Temperature, Humidity, Atmospheric Pressure and CO2 Transducers.
-
LAP-16128U -
Zeroplus Technology Corperation
Sample rate (Internal clock): 200MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Channels may be selectively defulted to /Channels: 16 CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals.
-
LAP-16064U -
Zeroplus Technology Corperation
Sample rate (Internal clock): 100MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Channels may be selectively defulted to /Channels: 16 CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals. Glitch Capture Capability: 5ns. Bandwidth: 75MHz.
-
LAP-321000U-A -
Zeroplus Technology Corperation
Sample rate (Internal clock): 200MHz asynchronous operation. Sample rate (External clock): 100MHz synchronous operation. Memory Depth (per channel): 1MbitsChannels: 32CH. Upgrade Oscilloscope to measure and decode I2C / UART (RS232C & RS485) / SPI Protocols and mixed signals. Glitch Capture Capability: 5ns. Bandwidth: 75MHz.
-
ND-6510 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
ND-6520 -
ADLINK Technology Inc.
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Model 290 -
Telebyte, Inc.
FEATURES: Break RS-485 Limit, Expand to 496 Nodes 16 Port Capacity; Each Port Settable to RS-422 or 2 Wire RS-485; Provides Isolation Between Ports; All Ports Surge Protected; Increased System Reliability. The Model 290 RS-232 to RS-422/RS-485 Concentrator offers a unique group of features for those applications using RS-422 and/or RS-485 for communications between a multiplicity of devices.